Electrical Specifications |
|
Continuous power rating |
|
250 kW AC |
|
Nominal AC voltage |
|
20 kV AC three phase (other levels on request) |
|
Nominal AC frequency |
|
50 Hz (60 Hz on request) |
|
Line power factor |
|
> 0.99 above 20% rated power |
|
AC current distortion |
|
<3% THD at rated power |
|
Nominal DC voltage rating |
|
600 VDC |
|
Maximum AC line current |
|
500 AAC |
|
Standby tare loss |
|
< 100 W |
|
Night consumption |
|
< 100 W |
|
Maximum AC line current |
|
164 amps AC |
|
Minimum DC voltage for feed-in |
|
450 VDC |
|
Suggested PV power |
|
280 kWp |
|
Maximum CD current |
|
555 A |
|
Max. open circuit voltage |
|
850 VDC (optional 880 VDC) |
|
Power tracking window range |
|
450 to 800 VDC |
|
Maximum efficiency |
|
96% at medium voltage level |
|
European efficiency |
|
95% at medium voltage level |
|
General Specifications |
|
Ambient temperature range |
|
-10 °C to +45 °C |
|
Enclosure environmental rating |
|
IP21 |
|
Enclosure |
|
Rittal TS Series |
|
Weight |
|
1160 kg |
|
Dimensions (H x W x D) |
|
211 x 200 x 60 cm |
|
Altitude |
|
up to 1500 m without de-rating |
|
Relative humidity |
|
0 to 95% non-condensing |
|
Features & Options |
|
Cooling method |
|
Forced convection cooling |
|
Protective functions |
|
AC over / under voltage, AC over / under frequency, over temperature, AC and DC over current, DC over voltage |
|
User display standard |
|
LCD, 4-line, 80-characters with keypad |
|
Disconnects (AC & DC) |
|
Integral to inverter assembly |
|
Isolation/medium voltage transformer |
|
Integral to turn key system |
|
Communications software |
|
Graphical user interface software for real time communications and control |
|
Data acquisition and logging |
|
Adjustable |
|
Interfaces |
|
Webserver or Telephone modem for remote system monitoring and faults notification |
|
Approvals & Safety |
|
The GT100E is compliant to applicable European Directive and CE marked |
|
The GT250E complies with the requirements of VDEW |
|
Note: Specifications subject to change without notice. |